Sl. No. Item Description UoM Comments MSETCL side SN EARTHING 19.00 "EARTHING & LIGHTNING PROTECTION SYSTEM - Supply installation testing & commissioning of Earth mat comprises preparation of existing earth, welding of MS flat and applying anti corrosive black paint after welding and laying of earth mat with back filling of soil." 19.01 CI Pipe 3 Meters Long, 13mm thick, inner Dia 150mm with Clamps Set 19.02 75x12 mm MS Flat (for Earth Mat) Mtrs 19.03 75 x 10 Copper Flat for Transformer body & Neutral Earthling Mtrs 19.04 75 x 10 GI Flat for GIS equipment Earthing Mtrs 19.05 50 x 6 mm GI flat for panels & other station auxiliary equipment earthling Mtrs 19.06 MS rod with spike at one end - 25 mm dia x 1mtr long required to be provided at earth mat periphery Nos. 19.07 Strain clamp suitable for 7/3.16 mm GI wire Nos. 19.08 Ground wire - GI 7/3.16 mm for Faraday's cage Mtrs 19.09 Copper Earth bond(flexible pig tail) 300 mm long with necessary clamps for lightning mast & gantry tower earth wire jumper connectivity. Nos. 19.10 Earth test link complete with disconnecting type link with necessary enclosure and hardwares and fixing brackets for the test link box Set 19.11 "Excavation & back filling of earth to a depth of 750 mm in substation area for providing necessary earth mat. Note: Bidder shall co-ordinate with civil contractor while excavating for cable cellar and construction of GIS building for successful completion of earth mat ." CuM 19.12 "Supply, Installation, testing and Commissioning of Hot drawn Copper Earth bars mounted on Stand-off insulators made out of halogen-free, fiberglass-reinforced thermoset unsaturated polyester moulded compound along with Stainless steel brackets. The Grounding bus shall be factory drilled holes for Cable end termination. Note-1 : Earth bus with Double Test links shall be provided wherever required Note-2: Earth bus shall be electro tin plated, Shall comply with NEMA standards" 19.12.1 450mm (L) x 100mm(W) x 10mm (T) Set 20.00 DIRECT STROKE LIGHTNING PROTECTION ( DSLP) 20.01 "Supply, installation testing & commissioning of DSLP Lightning Mast made out of hot dip galvanized lattice type steel structure complete with necessary Hard wares & spike at the top. Size: Base B/B - 600 x600 mm Height of the tower 18.5 Mtrs Peak (Spike) - 1.5 Mtrs" Set SECTION-IX GROUNDING ELECTRODES AND CONDUCTORS Note-1: The Installation shall strictly comply to IS3043 / IEEE80 codes Note-2 : Refer Single line diagram, Earthing schematic diagram for fault levels and PE sizes Note-3: All joints shall be properly welded joints and in case bolted joints, adequate size & numbers, bolts-nuts shall be used. Up to 25 x 6 flat, 2 bolts shall be used for joints. The size beyond 25mm width flat, 4 bolts shall be used. Bolted joints shall be with hexagonal bolt & nut with 2 flat washers & spring washers. "Note-4: Wherever dissimilar flats to be used, necessary bimetallic transition inserts shall be used for joining two flats, either to be welded respectively or with bolted joints as indicated above. But washers shall be with bimetallic. For Example : a) Copper-GI: Bimetallic transition inserts one side copper & another side GI b) Copper-Aluminium : Bimetallic transition inserts on one side copper & another side Aluminium c) Aluminium-GI: Bimetallic transition insert on side aluminium & anther side GI" Note-5: All buried flats shall be welded each other in addition to the bolted joints except wherever testing points only with bolted. Note-6: All copper earth bus shall be tinned copper type. Note-7: All earth conductor wires/cables shall be multistrand flexible type Note-8: All earth conductor wires/cables shall be of green colour type insulation GROUNDING ELECTRODES 1.1 Supply of materials, earth excavation, back filling, construction of chamber of dimension of 600mm(W)x600mm(B)x450mm(D), Providing Heavy duty chamber cover suitable for withstanding 5Ton Capacity and fixing of 0.6m x 0.6m x 4mm CU Plate earth station in conformity with IS 3043. The earth resistance shall be less than 1 Ohms. The Works shall include the heavy duty RCC chamber complete with cover, cable / strip termination, Labelling of resistance etc., All work shall be carried out in conformity with specifications, standards & Codes. Nos RO 1.2 Supply of materials, earth excavation, back filling, construction of chamber of dimension of 600mm(W)x600mm(B)x450mm(D), Providing Heavy duty chamber cover suitable for withstanding 5Ton Capacity andfixing of 100mm DIA GI Pipe earth station in conformity with IS 3043. The Works shall include the heavy duty RCC chamber complete with cover, cable / strip termination, Labelling of resistance etc., All work shall be carried out in conformity with specifications, sta
Submit Your Enquiry